OCT, fluorescein angiography and autofluorescence

Retinal imaging answers three different questions. Optical coherence tomography shows structure in cross-section, angiography shows blood flow and leakage, and autofluorescence shows the health of the retinal pigment epithelium. This lesson explains how each works, what normal looks like and how to name the abnormal patterns that exam questions describe.

11 minute read3 linked questions

How OCT works

Optical coherence tomography (OCT) is often described as ultrasound with light. A beam of near-infrared light is sent into the eye, and the machine measures how much is reflected back from each depth. Light travels far too fast for its echo delay to be timed directly, so OCT uses interferometry. The beam is split in two. One part goes to the retina and the other to a reference mirror. When the two returning beams are recombined they interfere, and the interference pattern reveals the depth and strength of each reflection.

One measurement down a single line is an A-scan: a profile of reflectivity against depth. Sweeping the beam sideways lines up thousands of A-scans into a cross-sectional picture, a B-scan. Stacking B-scans gives a three-dimensional block from which thickness maps are calculated.

The first machines, time-domain OCT, moved the reference mirror to sample each depth in turn and were slow. Spectral-domain OCT keeps the mirror still and analyses all wavelengths of the returning light at once with a spectrometer, reaching tens of thousands of A-scans a second with an axial resolution of about 5 micrometres. Swept-source OCT uses a laser that sweeps through longer wavelengths, around 1050 nm, which penetrate deeper and show the choroid. OCT needs no contact, no dye and often no dilation, and takes seconds. It does need reasonably clear media and a patient who can fixate.

The normal OCT

An OCT image is a map of reflectivity. Bright (hyper-reflective) tissue scatters light back. Dark (hypo-reflective) tissue lets it pass. By convention the vitreous is at the top and the choroid at the bottom.

The retina reads as alternating bands, and one rule explains most of them. Layers made of fibres and synapses, which run across the beam, are bright: the nerve fibre layer and the two plexiform layers. Layers made of cell bodies are dark: the ganglion cell layer (less dark than the others), the inner nuclear layer and the outer nuclear layer. Fluid is black.

Below the dark outer nuclear layer lie four thin bright lines that report the state of the photoreceptors.

  1. External limiting membrane: a faint line where Muller cells join the photoreceptors.
  2. Ellipsoid zone: a bright line from the mitochondria-packed inner segments, formerly called the inner segment and outer segment junction. A break in it means photoreceptor damage and predicts poor vision.
  3. Interdigitation zone: where the tips of the cone outer segments meet the pigment epithelium.
  4. Retinal pigment epithelium and Bruch membrane: the brightest band, which cannot normally be separated into its two parts.

At the fovea the inner layers are swept aside, leaving a pit lined only by photoreceptors. Loss of the pit is an early sign of macular swelling or traction.

3D atlasThe bright bands on OCT: the fibre and synaptic layers and the outer retinal lines.

Key OCT signs

FindingAppearanceTypical causes
Intraretinal fluidRound or oval black spaces within the retina; the retina is thickened and the foveal pit is lostDiabetic macular oedema, retinal vein occlusion, wet macular degeneration, cystoid macular oedema after surgery or in uveitis
Subretinal fluidA black space between the photoreceptors and the pigment epitheliumCentral serous chorioretinopathy, wet macular degeneration, retinal detachment
Pigment epithelial detachmentThe bright pigment epithelium line is lifted into a dome off Bruch membraneWet macular degeneration, central serous chorioretinopathy
DrusenSmall bumps under the pigment epithelium, giving it a wavy outlineAge-related macular degeneration
Full-thickness macular holeA gap through all layers at the fovea, often with fluid cysts in its rolled edgesVitreous traction at the fovea
Epiretinal membraneA thin bright line on the retinal surface with wrinkling of the inner retina beneathIdiopathic after posterior vitreous detachment; after retinal tears, surgery or inflammation
Vitreomacular tractionThe posterior vitreous face is still attached at the fovea and pulls it into a peakIncomplete posterior vitreous detachment
AtrophyThinning with loss of the outer bands; light passes through and brightens the choroid belowGeographic atrophy, old scars
Common OCT findings

Fluid matters because it guides treatment. In wet macular degeneration, diabetic macular oedema and vein occlusion, the decision to give or repeat an anti-VEGF injection rests largely on whether OCT shows fluid. Macular holes are sized on OCT: a hole of 250 micrometres or less is small and one over 400 micrometres is large.

Nerve fibre layer analysis and OCT angiography

Glaucoma kills ganglion cells, so their axons thin. OCT measures the retinal nerve fibre layer thickness around the optic disc along a circle, and the thickness of the ganglion cell layer at the macula. The circular profile normally has two humps, superior and inferior, where the arcuate bundles enter the disc. The machine compares each sector with a database of healthy eyes of the same age and colour-codes it: green for within the normal range, yellow for borderline and red for outside normal limits.

The colours need interpreting. A short-sighted eye or an unusual disc may be flagged red without disease, because the database does not represent it. A scan that is off-centre or of poor signal gives false thinning. In advanced glaucoma the measurement stops falling although damage continues, because glial tissue and vessels remain. Serial scans also follow recovery and atrophy after optic neuritis, and swelling of the disc.

OCT angiography shows vessels without dye. The same place is scanned several times in quick succession. Stationary tissue gives the same signal each time. Moving red cells change it, and the machine displays that change as flow. The result is a map of the capillary networks at chosen depths: the superficial and deep retinal plexuses and the choriocapillaris. It shows choroidal new vessels and areas of capillary closure, and measures the foveal avascular zone. Its limits are a small field, artefacts from eye movement and from superficial vessels projected onto deeper layers, and the fact that it shows flow only. It cannot show leakage, so it has not replaced dye angiography.

Fluorescein angiography: the normal sequence

Fluorescence is the absorption of light at one wavelength and its emission at a longer one. Sodium fluorescein absorbs blue light (465 to 490 nm) and emits yellow-green (520 to 530 nm). The camera shines blue light through an exciter filter and photographs through a barrier filter that passes only the green, so only dye is recorded. The usual adult dose is 500 mg, for example 5 mL of a 10% solution, injected quickly into an arm vein.

The test works because of the blood-retinal barrier. Fluorescein is a small molecule, about 80% bound to plasma protein, and the free fraction leaks from ordinary capillaries. Two barriers stop it in the eye. The inner barrier is the tight junctions between retinal capillary endothelial cells, so normal retinal vessels do not leak. The outer barrier is the tight junctions between retinal pigment epithelial cells, which keep dye that has leaked freely out of the fenestrated choriocapillaris from reaching the retina. Any fluorescein seen outside a vessel in the retina therefore means a barrier has failed.

  1. Choroidal phase, about 8 to 12 seconds after injection: a patchy background flush as the choroid fills. A cilioretinal artery, if present, fills now because it arises from the choroidal circulation.
  2. Arterial phase, 1 to 3 seconds later: the retinal arteries fill.
  3. Arteriovenous phase: capillaries fill and dye returns along the walls of the veins first, giving a striped (laminar) appearance.
  4. Venous phase: the veins fill completely. Fluorescence peaks at about 30 seconds.
  5. Late phase, up to about 10 minutes: dye has largely left the vessels. The disc margin and sclera stain normally.

The centre of the macula stays dark throughout. The fovea has no capillaries (the foveal avascular zone), and yellow macular pigment and dense pigment epithelium block the choroidal glow behind it.

Abnormal angiogram patterns and safety

Every abnormal area is either too bright (hyperfluorescent) or too dark (hypofluorescent). The pattern is named by how it changes over time.

PatternBehaviourMechanismExamples
LeakageBright; grows in size and intensity, with blurring edgesDye escapes from abnormal vessels or through a broken barrierNew vessels in diabetes, choroidal neovascularisation, cystoid macular oedema
PoolingBright; intensity rises but the area keeps its shapeDye fills a defined fluid spacePigment epithelial detachment, subretinal fluid in central serous chorioretinopathy
StainingBright late, with sharp edgesDye soaks into tissueDrusen, scars, sclera, the normal disc margin
Window defectBright early, fades with the choroid, never enlargesMissing pigment epithelium unmasks the choroidal flushGeographic atrophy, laser scars
Blocked fluorescenceDark throughoutSomething in front hides the dyeHaemorrhage, pigment, hard exudate
Filling defectDark because dye never arrivesVessels are closedCapillary non-perfusion in diabetes and vein occlusion, artery occlusion
Patterns on fluorescein angiography

Fluorescein is excreted by the kidneys and colours the urine for a day or so, and patients should be warned. Transient nausea is the commonest reaction, reported in roughly 3 to 15% of patients, and some vomit. Itching and urticaria are less common. Dye that escapes from the vein into the arm is painful. Severe reactions, including bronchospasm and anaphylaxis, are rare, and death has been estimated at about 1 in 220,000. Resuscitation equipment must be at hand and consent taken. The test is generally avoided in pregnancy unless essential.

Indocyanine green and autofluorescence

Fluorescein shows the choroid poorly. Its blue and green light is absorbed and scattered by the pigment epithelium, and the dye pours out of the choriocapillaris and blurs the picture. Indocyanine green (ICG) solves both problems. It absorbs and emits in the near-infrared (about 790 and 835 nm), which passes through pigment, thin haemorrhage and fluid. It is about 95% protein bound, so it stays inside the choroidal vessels. ICG is the test for the choroid: polypoidal choroidal vasculopathy, central serous chorioretinopathy, choroidal haemangioma and inflammatory diseases of the choroid. Adverse reactions are uncommon. The dye contains iodide, and it is customarily avoided in people with iodine allergy.

Fundus autofluorescence needs no dye. The pigment epithelium digests the shed tips of photoreceptor outer segments throughout life, and the indigestible residue accumulates as lipofuscin, which fluoresces when lit with blue light of about 488 nm. The image is therefore a map of lipofuscin, and so of pigment epithelial health. Normal fundus glows evenly. The disc is dark because it has no pigment epithelium, the vessels are dark because blood absorbs the light, and the fovea is dim because macular pigment absorbs blue.

Dark areas (hypoautofluorescence) mean the pigment epithelium is dead or hidden: geographic atrophy shows as sharply defined black patches, often with a brighter rim of stressed cells that marks where atrophy will spread. Bright areas (hyperautofluorescence) mean excess lipofuscin or a similar fluorophore: the yellow deposit of Best disease, optic disc drusen, and the bright ring around the macula in retinitis pigmentosa. Autofluorescence is used to follow geographic atrophy and inherited retinal dystrophies and to screen for hydroxychloroquine retinopathy.

Summary

  • OCT uses interferometry of near-infrared light to build cross-sections of the retina from A-scans.
  • On OCT, fibre and synaptic layers are bright, nuclear layers are dark and fluid is black.
  • The ellipsoid zone reflects photoreceptor integrity; its loss predicts poor vision.
  • Intraretinal fluid lies in cysts within the retina, subretinal fluid lies above the pigment epithelium, and a pigment epithelial detachment lies below it.
  • Nerve fibre layer thickness around the disc is compared with a normal database to detect and follow glaucoma.
  • OCT angiography maps flow without dye but cannot show leakage.
  • Fluorescein is excited by blue light and emits yellow-green; normal retinal vessels and the pigment epithelium do not let it through.
  • Leakage enlarges, pooling fills a space, staining is late and sharp, and a window defect is early and fades.
  • Hypofluorescence is either blockage by something in front or non-perfusion.
  • Indocyanine green images the choroid; autofluorescence maps lipofuscin in the pigment epithelium.

Check yourself

Quick recall on this lesson. These are easier than the question bank.

1. Which retinal layer appears dark (hypo-reflective) on OCT?
2. An area of hyperfluorescence appears early, keeps the same size and fades late. What is it?
3. Which substance is responsible for the signal in fundus autofluorescence?
4. What can fluorescein angiography show that OCT angiography cannot?
Practise 3 questions on this lesson

Written for revision. It is not a source of clinical advice, and guidance changes.