What glaucoma is: pressure, the optic disc and the visual field
Glaucoma is a group of diseases that damage the optic nerve in a recognisable pattern. This lesson explains what that pattern is, where intraocular pressure fits in, and how pressure, the optic disc, the visual field and the drainage angle are examined. Every later glaucoma lesson assumes this vocabulary.
An optic neuropathy, not a pressure reading
Glaucoma is a progressive optic neuropathy: a disease in which retinal ganglion cells and their axons die, producing a characteristic excavation of the optic disc (cupping) and matching defects in the visual field. The damage is permanent, because ganglion cells do not regenerate.
Raised intraocular pressure (IOP) is the main risk factor and the only one that treatment can change, but it is not part of the definition. Many people with pressures above the normal range never develop nerve damage (ocular hypertension), and some develop typical glaucomatous damage at pressures that are statistically normal (normal tension glaucoma). Glaucoma is diagnosed from the disc and the field. Pressure tells you about risk and is the thing you treat.
Two questions classify any glaucoma. First, is the drainage angle open or closed, which is answered by gonioscopy. Second, is there an identifiable cause (secondary glaucoma) or not (primary). Primary open-angle glaucoma, the commonest form in the UK, is painless and symptomless until late, which is why it is usually found by an optometrist and not by the patient.
Where the pressure comes from
Aqueous humour is secreted by the non-pigmented epithelium of the ciliary processes into the posterior chamber, at about 2 to 3 microlitres per minute while awake and roughly half that during sleep. It passes forward through the pupil into the anterior chamber and leaves the eye by two routes.
- The trabecular (conventional) route carries most of the outflow: through the trabecular meshwork in the angle, into Schlemm's canal, then through collector channels to the episcleral veins.
- The uveoscleral route carries a minority: through the face of the ciliary body into the suprachoroidal space. Prostaglandin analogues work by increasing it.
IOP settles where inflow equals outflow. It therefore depends on three things: the rate of aqueous production, the resistance to outflow through the meshwork, and the pressure in the episcleral veins that the aqueous drains into (about 8 to 10 mmHg). In almost every glaucoma the fault is increased resistance to outflow, not overproduction. Every treatment acts on one of these terms: reducing production, or improving outflow.
In population studies the mean IOP is about 15.5 mmHg with a standard deviation of about 2.6 mmHg. The traditional upper limit of 21 mmHg is simply two standard deviations above the mean. It is a statistical boundary, not a safe threshold.
Measuring pressure
Goldmann applanation tonometry, mounted on the slit lamp, is the reference method and the one NICE requires for diagnosis and monitoring. It rests on the Imbert-Fick principle: the pressure inside an ideal thin-walled sphere equals the force needed to flatten part of its surface divided by the area flattened.
The cornea is anaesthetised and stained with fluorescein, and a prism is advanced under cobalt blue light until it flattens a circle 3.06 mm in diameter. The examiner sees two green semicircles and turns the dial until their inner edges just touch. Goldmann chose 3.06 mm because at that size the pull of tear surface tension and the resistance of the cornea cancel out, and because the force in grams multiplied by ten then gives the pressure in mmHg.
The cornea is not an ideal membrane, so its properties alter the reading. Goldmann assumed a central corneal thickness of about 520 micrometres. A thicker cornea resists flattening and gives a falsely high reading. A thinner cornea, including one thinned by laser refractive surgery, gives a falsely low one. This is why NICE asks for corneal thickness to be measured when glaucoma is being diagnosed, and why a thin cornea is treated as a risk factor: the true pressure is higher than it looks.
| Factor | Effect on the reading |
|---|---|
| Thick central cornea | Reads falsely high |
| Thin central cornea, or previous laser refractive surgery | Reads falsely low |
| Breath holding, straining, a tight collar or tie | Raises the pressure itself while measured |
| Marked corneal astigmatism | Distorts the semicircles unless the prism is rotated |
Non-contact (air puff) tonometry is quick and needs no drops, but it is less accurate at the extremes. NICE states that a decision to refer should not rest on a non-contact reading alone.
Reading the optic disc
The axons of the retinal ganglion cells leave the eye at the optic disc. They form the pink neuroretinal rim, and the central pale depression that contains no axons is the cup. As axons die the rim thins and the cup enlarges, so the disc is a direct view of how many axons remain.
3D atlasThe cup is the central depression of the disc. Glaucoma enlarges it at the expense of the rim.The cup-to-disc ratio is the diameter of the cup as a fraction of the disc, usually judged vertically because glaucoma thins the rim at the upper and lower poles first. A single ratio is weak evidence on its own, because large discs have large cups normally. More useful are a difference of 0.2 or more between the two eyes, and change over time.
- ISNT rule: a healthy rim is thickest Inferiorly, then Superiorly, then Nasally, and thinnest Temporally. Glaucoma thins the inferior and superior rim and breaks the rule.
- Notching: a focal loss of rim, typically at the inferior or superior pole, with a matching wedge defect in the nerve fibre layer.
- Disc haemorrhage (Drance haemorrhage): a small flame or splinter haemorrhage across the disc margin, usually inferotemporal or superotemporal. It suggests active disease and is seen more often in normal tension glaucoma.
- Peripapillary atrophy: a crescent of chorioretinal thinning beside the disc. It is common in glaucoma but is not specific.
- Vessel signs: vessels bend sharply over the edge of a deep cup, and a vessel that once ran along the cup margin is left bare as the rim recedes.
Why the field defects look the way they do
The shape of glaucomatous field loss follows the course of the nerve fibres. Fibres from the temporal retina cannot cross the fovea, so they arch above and below it and meet along a horizontal line, the horizontal raphe. These arcuate fibres enter the disc at its superior and inferior poles, exactly where the supporting tissue is weakest and damage begins. Fibres from the macula run straight to the temporal side of the disc and are spared until late.
| Defect | What it is | Why it happens |
|---|---|---|
| Paracentral scotoma | A small island of loss close to fixation, often superonasal | Loss of a small bundle of arcuate fibres |
| Nasal step | A step in sensitivity across the horizontal midline on the nasal side | Upper and lower arcuate bundles are damaged unequally, and they meet at the horizontal raphe |
| Arcuate (Bjerrum) scotoma | An arc of loss sweeping from the blind spot around fixation to the nasal horizontal | Loss of a whole arcuate bundle |
| Tunnel vision | Only a central island remains, sometimes with a temporal island | The macular fibres survive longest |
Two rules follow. Glaucomatous defects respect the horizontal midline, whereas defects from chiasmal and post-chiasmal disease respect the vertical. And central acuity is preserved until late, so a normal 6/6 does not exclude advanced glaucoma. Fields are tested with standard automated perimetry, which measures the dimmest stimulus seen at each point of the central field.
OCT and gonioscopy
Optical coherence tomography (OCT) gives a cross-sectional image of the retina. In glaucoma it is used to measure the thickness of the retinal nerve fibre layer in a ring around the disc, and of the ganglion cell layer at the macula, and to compare them with a database of healthy eyes. Thinning in the inferior and superior sectors mirrors what is seen at the disc. Its strengths are objectivity and the ability to show change between visits. It supports the clinical examination but does not replace it.
3D atlasGlaucoma thins the ganglion cell layer and the nerve fibre layer formed by its axons.Gonioscopy is the examination of the drainage angle. The angle cannot be seen directly because light from it is totally internally reflected at the tear-air interface. A contact lens placed on the cornea removes that interface, and a mirror in the lens shows the opposite angle.
From the cornea backwards the landmarks are Schwalbe's line (the edge of Descemet's membrane), the trabecular meshwork, the white scleral spur and the ciliary body band. If the meshwork can be seen all the way round, the angle is open. If the iris hides it, the angle is narrow or closed. Pressing gently with the lens (indentation) shows whether closure is by simple contact or by permanent adhesions called peripheral anterior synechiae. Gonioscopy also reveals causes of secondary glaucoma, such as heavy pigment, new vessels or a torn ciliary body.
The van Herick test is a slit lamp estimate that compares the depth of the peripheral anterior chamber with the thickness of the adjacent cornea. NICE accepts it for case-finding when gonioscopy is not available, but gonioscopy is required for diagnosis.
Summary
- Glaucoma is a progressive optic neuropathy defined by disc cupping and matching field loss, not by pressure.
- Raised intraocular pressure is the main modifiable risk factor, and 21 mmHg is only two standard deviations above the population mean.
- Aqueous is made by the ciliary processes and leaves mostly through the trabecular meshwork and Schlemm's canal, with a minority by the uveoscleral route.
- Goldmann applanation flattens a 3.06 mm circle of cornea and is the reference method for measuring pressure.
- A thick cornea makes Goldmann read falsely high and a thin cornea makes it read falsely low.
- Glaucoma thins the inferior and superior rim first, breaking the ISNT rule and producing notches and a large vertical cup-to-disc ratio.
- A disc margin haemorrhage suggests active glaucomatous damage.
- Typical field defects are the paracentral scotoma, nasal step and arcuate scotoma, all respecting the horizontal midline.
- Central vision is spared until late, so normal acuity does not exclude advanced glaucoma.
- Gonioscopy shows whether the angle is open or closed, and is needed because of total internal reflection at the cornea.
Check yourself
Quick recall on this lesson. These are easier than the question bank.
Written for revision. It is not a source of clinical advice, and guidance changes.